Preface

This is the third edition of CSA N285.5, Periodic inspection of CANDU nuclear power plant containment components. It supersedes the previous editions published in 1990 and 1988.

1 Scope

1.1 This Standard specifies requirements for the periodic inspection of containment system components, including containment pressure suppression systems, in CANDU nuclear power plants.

1.2 The inspection requirements specified in this Standard provide assurance of the structural integrity of metallic and plastic containment system components.
Note: The following are addressed by other Standards or procedures as specified in Table 1:
(a) leak tightness and operability requirements; and
(b) inspection and testing requirements for concrete, embedded parts, and elastomeric seals.

1.3 This Standard specifies requirements for
(a) inspection;
(b) accessibility;
(c) inspection methods and procedures;
(d) personnel qualifications;
(e) inspection criteria;
(f) inspection program development;
(g) inspection frequency;
(h) evaluation of inspection results;
(i) disposition of defects;
(j) repairs;
(k) documentation; and
(l) records.

1.4 In CSA Standards, "shall" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; "should" is used to express a recommendation or that which is advised but not required; "may" is used to express an option or that which is permissible within the limits of the standard; and "can" is used to express possibility or capability. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.
Edition : 3rd
File Size : 1 file , 1.1 MB
ISBN(s) : 9781554367979
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 48
Product Code(s) : 2419572, 2020130
Published : 11/01/2008

History

CAN/CSA N285.5-13 (R2018)
Published Date: 07/01/2013
Periodic Inspection of CANDU Nuclear Power Plant Containment Components
$597
CAN/CSA N285.5-08
Published Date: 11/01/2008
Periodic Inspection of CANDU Nuclear Power Plant Containment Components
$597
CAN/CSA N285.5-M90 (R2005)
Published Date: 01/17/2000
Periodic Inspection of CANDU Nuclear Power Plant Containment Components
$33

Related products

CAN/CSA E335-2-68-94
Published Date: 04/01/1994
Safety of Household and Similar Electrical Appliances - Part 2: Particular Requirements for Spray Extraction Appliances, for Industrial and Commercial Use (Based on IEC'S first edition) and Canadian Deviations (Adopted IEC 335-2-68:1992 with modifications) / Securite des appareils electrodomestiques
$20.4
CAN/CSA Z243.175-91 (R2000)
Published Date: 05/04/2000
Information Technology - Open Systems Interconnection - Virtual Terminal Basic Class Service (Adopted ISO 9040:1990)
$37.8
CAN/CSA C22.2 NO. 4248.4:24
Published Date: 06/25/2024
Fuseholders - Part 4: Class CC (Trinational standard with UL 4248-4 and NMX-J-009/4248/4-ANCE-2024)
$97.5

Best-Selling Products